Discover our Field Probes
probes-E-H1-400
E & H (1 Hz – 10 MHz)
1 Hz - 10 MHz - E & H field
10 Hz - 3 kHz - E & H field
1 Hz - 400 kHz - E & H field
1 Hz - 400 kHz - E & H field
1 Hz - 400 kHz - E & H field
probes-E100-60
E (100 kHz - 60 GHz)
100 kHz - 3 GHz - E field
100 kHz - 6 GHz - E field
100 kHz - 8 GHz - E field
300 kHz - 18 GHz - E field
1 MHz - 40 GHz - E field
1 MHz - 60 GHz - E field
1 MHz - 60 GHz - E field
probes-H300-1000
H (300 kHz – 1000 MHz)
300 kHz - 60 MHz - H field
30 MHz - 1000 MHz - H field
WPH DC 40 miniH (DC - 40 kHz)
DC - 40 kHz - H Field

 

Can’t find the field probe you need? Ask us! We may have it or be able to supply you with a customised product.

EMF safety field probe selection chart DC 180207


WP10M Field Probe

1 Hz - 10 MHz
E & H field
Selective & Broadband

mini wp400

 

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Automotive

In accordance with IEC/EN 61786-1.

Data sheet     REQUEST A QUOTE →

WP400

Compatible with:

smp3
SMP3


WP50 Field Probe

10 Hz - 3 kHz
E & H field
Broadband

mini wp400

 

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Induction heating: EN 50519
  • Electric arc or induction smelting
  • Workplace assessment: EN 50499
  • Human exposure assessment: EN 50413
  • Other low frequency applications

In accordance with IEC/EN 61786-1.

Data sheet     REQUEST A QUOTE →

WP50

Compatible with:

smp3
SMP3

SMP2
monitem
MonitEM


WP400 Field Probe

1 Hz - 400 kHz
E & H field
Selective & Broadband

mini wp400

 

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Automotive

In accordance with IEC/EN 61786-1.

Data sheet     REQUEST A QUOTE →

WP400

Compatible with:

smp3
SMP3

SMP2


WP400c Field Probe

1 Hz - 400 kHz
E & H field
Selective & Broadband

mini wp400

 

MAIN APPLICATIONS

  • Automotive
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defense (LF) 
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.
GB 8702-2014 limit included
Data sheet     REQUEST A QUOTE →

WP400

Compatible with:

smp3
SMP3

SMP2


WP400-3 Field Probe

1 Hz - 400 kHz
E & H field
Selective & Broadband

mini wp400-3

 

MAIN APPLICATIONS

  • Assessment of:
    • Welding equipment: IEC/EN 62822, EN 50505
    • Household appliances: IEC/EN 62233, EN 50366
    • Other electronic/electrical equipment: IEC/EN 62311
  • Research/Labs 
  • Other application where small size and spatial resolution is important

In accordance with IEC/EN 61786-1.

Data sheet     REQUEST A QUOTE →

WP400-3

Compatible with:

smp3
SMP3

SMP2


WPF3 Field Probe

100 kHz - 3 GHz
E field
Broadband

mini wpf3

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

Data sheet     REQUEST A QUOTE →

WPF3

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF6 Field Probe

100 kHz - 6 GHz
E field
Broadband

mini wpf6

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

Data sheet     REQUEST A QUOTE →

WPF6

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF8 Field Probe

100 kHz - 8 GHz
E field
Broadband

mini wpf8

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying

Data sheet     REQUEST A QUOTE →

WPF8

Compatible with:

emf meter Smp2
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF18 Field Probe

300 kHz - 18 GHz
E field
Broadband

mini wpf18

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defense (HF)

Data sheet     REQUEST A QUOTE →

WPF18

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF40 Field Probe

1 MHz - 40 GHz
E field
Broadband

mini wpf40

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

Data sheet     REQUEST A QUOTE →

WPF40

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPF60 Field Probe

1 MHz - 60 GHz
E field
Broadband

mini wpf40

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

Data sheet     REQUEST A QUOTE →

WPF40

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab

 


WPF60S Field Probe

1 MHz - 60 GHz
Shaped (FCC / ICNIRP)
E field - Broadband

mini wpf40

 

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
    • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defense (HF)

Data sheet     REQUEST A QUOTE →

WPF40

Compatible with:

emf meter Smp3
SMP3

SMP2

 


WPH60 Field Probe

300 kHz - 60 MHz
H field
Broadband

mini wph60

 

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs

Data sheet     REQUEST A QUOTE →

WPH60

Compatible with:

smp3
SMP3

SMP2
monitem
MonitEM


WPH1000 Field Probe

30 MHz - 1000 MHz
H field
Broadband

mini wph1000

 

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Defence

Data sheet     REQUEST A QUOTE →

WPH1000

Compatible with:

emf meter Smp3
SMP3

SMP2
Area monitoring Monitem
MonitEM

Area monitoring Monitem-lab
MonitEM-Lab


WPH-DC Probe

DC - 40 kHz
H Field
Selective & Broadband

WPH-DC

 

APPLICATIONS

  • Medical (MRI: Magnetic Resonance Imaging): IEC 60601-2-33
  • Railway (DC Motors): EN 50500
  • Automotive (Electrical vehicles)
  • Chemical Industry (Electrolysis)
  • Strong Permanent Magnets (Heavy duty magnet lifters)
  • Energy (DC generators)
  • Metrology (Earth static field)



Data sheet     REQUEST A QUOTE →

WPH-DC

Compatible with:

smp3
SMP3

SMP2

Can’t find the field probe you need? Ask us! We may have it or be able to supply you with a customised product.

W 208 margen

Wavecontrol S.L.
Carrer de Pallars 65-71
08018 Barcelona (Spain)
European Union
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tel +34 933 208 055
 
              

Wavecontrol Inc.
101 Eisenhower Pkwy Suite 300
Roseland, NJ 07068-1054
United States of America
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tel +1 201 479 9022
 

feedback
How can we help you?
x


Our Cookie Policy


This website uses cookies to improve your experience. By continuing to use this website you are giving consent to cookies being used. More info here.