Explore Our Field Probes Family

Complete range of field probes to cover all your needs and requirements.

  • Isotropic (3 axis) probes
  • High performance
  • DC up to 90 GHz
  • Electric and Magnetic fields
  • FFT (frequency analysis)
  • All probes compatible with SMP3 meter
  • ISO17025 calibrated
Request a Quote

All field probes

DC1 Hz10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz10 MHz100 MHz1 GHz10 GHz100 GHz Magnetic Field - H WP10M — 1 Hz - 10 MHzWPH60 — 300 kHz - 60 MHzWPH1000WPF3 — 100 kHz - 3 GHzWPF6 — 100 kHz - 6 GHzWP50 — 10 Hz - 3 kHzWP400, WP400c, WP400-3 — 1 Hz - 400 kHzWPH-DC — DC - 40 kHzWPF8 — 100 kHz - 8 GHzWPF18 — 1 MHz - 18 GHzWPF40 — 1 MHz - 40 GHzWPF60, WPF60s — 1 MHz - 60 GHz30 MHz - 1000 MHz Electric and Magnetic Field - E&HElectric Field - EWPF90 — 30 MHz - 90 GHz

Discover the Field Probe that Best Suits Your Application

WPH-DC Probe

DC – 40 kHz

H field

Selective & Broadband

MAIN APPLICATIONS

  • Medical (MRI: Magnetic Resonance Imaging): IEC 60601-2-33
  • Railway (DC Motors): EN 50500
  • Automotive (Electrical vehicles)
  • Strong Permanent Magnets (Heavy duty magnet lifters)
  • Energy (DC generators)

In accordance with IEC/EN 61786-1.

WP50
Compatible with:

xxx

SMP3

SMP3

WP50 Field Probe

10 Hz – 3 kHz

E & H field

Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Induction heating: EN 50519
  • Electric arc or induction smeltingEN 50505
  • Workplace assessment:EN 50499
  • Human exposure assessment:EN 50413
  • Other low frequency applications

In accordance with IEC/EN 61786-1.

WP50
Compatible with:

xxx

SMP3

SMP3


WP400 Field Probe

1 Hz – 400 kHz

E & H field

Selective & Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

WP50
Compatible with:

xxx

SMP3

SMP3


WP400-3 Field Probe

1 Hz – 400 kHz

E & H field

Selective & Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
    • Welding equipment: IEC/EN 62822, EN 50505
    • Household appliances: IEC/EN 62233, EN 50366
    • Other electronic/electrical equipment: IEC/EN 62311
  • Research/Labs
  • Other application where small size and spatial resolution is important

In accordance with IEC/EN 61786-1.

WP50
Compatible with:

xxx

SMP3

SMP3


WP400c Field Probe

1 Hz – 400 kHz

E & H field

Selective & Broadband

MAIN APPLICATIONS

  • Automotive
  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

GB 8702-2014 limit included

WP50
Compatible with:

xxx

SMP3

SMP3


WP10M Field Probe

1 Hz – 10 MHz

E & H field

Selective & Broadband

MAIN APPLICATIONS

  • Energy: IEC/EN 62110
  • Railway: EN 50500
  • Welding: EN 50505
  • Induction heating (LF): EN 50519
  • Electric arc or induction smelting
  • Household appliances: IEC/EN 62233, EN 50366
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Medical: IEC 60601
  • Research/Labs
  • Electronic/electrical equipment: IEC/EN 62311
  • Defence (LF)
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413

In accordance with IEC/EN 61786-1.

WP50
Compatible with:

xxx

SMP3

SMP3

WPF3 Field Probe

100 kHz – 3 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF):EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical:IEC 60601
  • Workplace assessment:EN 50499
  • Assessment of workers bearing AIMDs:EN 50527-1
  • Human exposure assessment:EN 50413
  • Research/Labs
  • Microwave drying
WP50
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF6 Field Probe

100 kHz – 6 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF):EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical:IEC 60601
  • Workplace assessment:EN 50499
  • Assessment of workers bearing AIMDs:EN 50527-1
  • Human exposure assessment:EN 50413
  • Research/Labs
  • Microwave drying
WP50
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF8 Field Probe

100 kHz – 8 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401, EN 50492
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF):EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical:IEC 60601
  • Workplace assessment:EN 50499
  • Assessment of workers bearing AIMDs:EN 50527-1
  • Human exposure assessment:EN 50413
  • Research/Labs
  • Microwave drying
WPF8
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF18 Field Probe

100 kHz – 18 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Plastic welding
  • Semiconductor production
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Radar
  • Defence (HF)
WPF18
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF40 Field Probe

1 MHz – 40 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50400, EN 50401
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
WPF40
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF60 Field Probe

1 MHz – 60 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50600, EN 50601
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
WPF60
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab


WPF60s Field Probe

1 MHz – 60 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50600, EN 50601
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
WPF60s
Compatible with:

xxx

SMP3

SMP3


WPF90 Field Probe

30 MHz – 90 GkHz

E field

Broadband

MAIN APPLICATIONS

  • Telecommunications:
    • Wireless telecom networks: IEC 62232, EN 50600, EN 50601
    • Broadcast: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • Satellite installations
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Microwave drying
  • Detection of leaks
  • Radar
  • Defence (HF)
WPF60s
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab

WPH60

300 kHz – 60 GHz

H field

Broadband

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
WPH60
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM


WPH1000

30 MHz – 1000 MHz

H field

Broadband

MAIN APPLICATIONS

  • Broadcasting: IEC 62577, EN 50475, EN 50476, EN 50496, EN 50554
  • RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1
  • Induction heating (HF): EN 50519
  • Medical: IEC 60601
  • Workplace assessment: EN 50499
  • Assessment of workers bearing AIMDs: EN 50527-1
  • Human exposure assessment: EN 50413
  • Research/Labs
  • Defense
WPH60
Compatible with:

xxx

SMP3

SMP3

Monitem

MonitEM

SMP3

MonitEM-Lab

wavecontrol

Calibrations

Wavecontrol offers ISO 17025 accredited official calibrations through LabCal, our own calibration laboratory based in Barcelona, Spain. LabCal Wavecontrol specialises in the calibration of E and H field probes. With our experience in over 10,000 accredited calibrations to date, LabCal is fully equipped to allow us to calibrate from the static field (0 Hz) up to 90 GHz.

Calibration Scope Document

Acredited Calibration Ilac ENAC ISO 17025 Wavecontrol

Do you need to calibrate a Wavecontrol or a third party product?

Online RMA Form

Application of EMF Wavecontrol Devices

Automotive

Drivers and passengers of automotive vehicles are exposed to significant low-frequency magnetic fields emitted by different electrical and electronic components in these vehicles. With a higher demand for electric cars to minimize pollution and enforce decarbonization, there is an increased EMF risk which must be assessed to ensure that the vehicle users are safe from overexposure to EMF.

International organizations and car manufacturers have developed standards to check that automotive vehicles comply with national and international EMC safety regulations. This assessment must be done from DC to 400 kHz. Some of the standards that define these procedures for assessing LF magnetic fields in vehicles include IEC 62764, GB/T 37130, MBN 10284-2, PSA-MR02 B217110 and many others.

Industry

Workers’ exposure to electromagnetic fields must be monitored for their safety in a wide range of industrial areas, machinery and manufacturing processes. Some examples include induction heating, welding systems and processes, radio frequency (RF) heating, tempering and drying equipment, chemical processes (electrolysis), etc.

Home appliances also generate electromagnetic fields that must be measured and evaluated before they can be put on the market. The applicable reference standards include: EN 50519 (induction heating), IEC/EN 62822-1, IEC/EN 62822-2 and IEC/EN 62822-3 (welding), IEC 62233 (household appliances), IEC 62493 (lighting), EN 50527 (workers bearing active implantable medical devices), etc.

Energy

Low frequency electromagnetic fields are associated mainly with the supply of electricity, through the generation, distribution and use of alternating current (AC), and they are always present in our surroundings. Electricity operates at the frequency of 50 Hz or 60 Hz, depending on the country.

Electric power stations, high- and medium-voltage lines, transformers, electric motors and railway lines are the main sources of these electromagnetic fields. The applicable reference standards include: IEC/EN 62110 (AC power systems), IEC 61786-1 and IEC 61786-2 (measurement of DC and AC fields from 1 Hz to 100 kHz).

Radar Aerospace

The main sources of electromagnetic radiation in the area of radars and aerospace are radar stations, satellite equipment, communication equipment, etc. The SMP3 is particularly suitable thanks to its high-speed digital processing that ensures the ability to detect peaks of up to 1 µs. It can also detect isolated very high amplitude peaks thanks to a special self-scaling function that adapts the device’s dynamic margin (amplification) to the necessary levels.

In the area of radar/aerospace we can find electric and magnetic fields of low frequency, from communications equipment working at several kilohertz (kHz) up to gigahertz (GHz). The SMP3 + WP400 + WPF18 combination is ideal in this case because it can cover the 1 Hz – 18 GHz frequency range with just two probes.

Laboratories R+D

Electric/electronic laboratories normally use radiofrequency equipment and the levels of electromagnetic radiations can therefore be high. This makes it necessary to ensure workers’ safety in connection with exposure to those electromagnetic fields.

To ensure that permitted levels of exposure are not exceeded, the ideal devices are broadband meters that can measure total exposure over the working frequency range of the equipment used. The ideal solution is the SMP3 + the WPF probe that is best suited to the frequency range in question. Wavecontrol also produces continuous measurement systems with built-in alarm, based on the MonitEM devices, designed for monitoring exposure in this sort of facility.

Detection of articles and persons (RFID/EAS)

Radio frequency identification (RFID) and electronic article surveillance (EAS) systems are commonly used in public spaces, generating complex electric fields.

People who work in spaces near those systems are exposed more intensely than people who are passing through them. Most of those systems work in the low frequency range. The reference standards applicable to exposure to RFID/EAS are: EN 50364 and IEC/EN 62369-1.

Telecommunications

Cell phone systems, broadcasting systems and other communication systems are the main sources of electromagnetic radiation in this area. Measurements are sometimes taken under far field conditions, where use of an E (electric) field probe will be sufficient (e.g. WPF8). With low frequency transmitters, we may find ourselves in near field conditions and so the H (magnetic) field will also have to be measured (e.g. WPH60).

It is important that personnel who access telecommunication infrastructures or climb towers with radiating elements, do so with personal protective equipment such as the WaveMon personal monitor, to avoid overexposure.

Some international reference standards are: IEC 62232 and EN 50492 (base stations), EN 50496, EN 50554, EN 50475 and EN 50476 (broadcasting), EN 50400 and EN 50401 (radio communication equipment).

Electromedicine

Magnetic resonance equipment, diathermy and hyperthermia equipment, and electrosurgery equipment are the main sources of electromagnetic radiation in the medical industry.

The medical staff using that equipment or working in nearby spaces are exposed more intensely than patients or people who are passing through, and so exposure within the radius of influence of that equipment must be evaluated and controlled. This includes measurements at low and high frequencies using the suitable devices and probes with isotropic response and RMS. The applicable standard is IEC 60601.

Railway

Electricity is very important in the rail industry, since it allows trains to move quickly, quietly, comfortably and with little pollution. High-power and low-frequency energy is used for moving trains and radio frequencies (RF) are used for communication.

People’s exposure to electromagnetic fields both inside and outside trains, near communication systems and in stations must be controlled. The standard EN 50500 defines procedures for measuring the levels generated in the rail industry in connection with human exposure.

Our Address

Wavecontrol S.L.

Carrer de Pallars 65-71
08018, Barcelona – Spain
European Union
info@wavecontrol.com
+34 933 208 055

Wavecontrol Inc.

101 Eisenhower Pkwy Suite 300
Roseland, NJ 07068-1054
United States of America
sales@wavecontrol.com
+1 201 479 9022

Tell us about your next project